Nồi hấp cửa trước

Tủ hấp tiệt trùng, HS-4085,Hanshin,Korea

Tủ hấp tiệt trùng, HS-4085,Hanshin,Korea

 
 
Home Sterilizer Steam Sterilizer
멸균기 │ 고압증기멸균기 시리즈
 
85 liters
 
 HS-4085   HS-4085G(Gravity) 
 
 
 

HS-4085 
 
 
 

1. Substantial Chamber Capacity
This sterilizer, which has a practical medium sized chamber between large and small sized sterilizer and is very effective to load the volumed loads, uses the saturated vapor as sterilant supplied from the built-in steam generator or external steam supply system. The cylindrical chamber with jacket is the most sound structurally and the door is sealed firmly by a locking system with radial levers. The optional type is very convenient to operate and control the sterilizer by the touch screen LCD and could monitor the cycle processing in real time on the screen monitor.



2. Variable Cycle Programs and Self-Diagnosis Program
This sterilizer has 5 kinds of optimized basic cycle program for sterilizing general medical instruments and 2 kinds of test program are embedded in the controls of sterilizer. Therefore operator can select a proper cycle conveniently for sterilizing a load and change the parameters of program easily according to the sterilizing condition. The self-diagnosis program generates the warning signal, displays the error code on the control panel and aborts the executing cycle for safety automatically in case that any operating error has occurred during cycle executing.



3. Safety
The door would not be opened without power supplying and cycle does not start unless the door is locked. The door locking system is designed to seal the chamber simply by the radial lever type. To open the door safely under chamber pressure, turn the door handle counter clockwise, then the radial levers are released and the vapor is leaked through the gap between chamber edge and door. Strong opening/closing mechanism and heat-blocking door plate cover would protect the operator from a possible accident during sterilizing. In case the chamber pressure exceeds in the set value, the safety valve exhausts the vapor from the chamber and then decreases the chamber pressure.



4. Built-in Printer
The built-in panel printer prints out the cycle performance record for securing the traceability afterwards.
 
 
 
 
 
Model HS-4085
Overall Dimension W840 x D1,097 x H1,575 ㎜
Chamber Ø400 x L680 ㎜,   Vol:  85.4ℓ,   Material:  STS 316L
Loading Shelf W355 x D640 ㎜   Q ty:  2 EA,   W150 x D648 ㎜   Q ty:  1 EA
Operating Temperature 121.0℃ ~ 135.0℃
Air Removal Vacuum / Gravity
Controls Microprocessor
Display Standard type Graphic LCD (LED back-light),  Resolution;  160 x 128 dots
Optional type Touch Type Color TFT LCD,  Resolution;  320 x 240
Printer Direct Thermal Printing,  Printing paper roll:  W58 x Ø40 mm
Power Source Built-in Steam Generator :  AC 230V, 3Ph, 50/60㎐, 26A   or  
                                                 AC 380V, 3Ph, 4Wire, 50/60㎐, 15A
External Steam Only :  AC230V, 50/60㎐, 5A
Steam Source Built-in Steam Generator :  Heater  9 KW,   Water Pump :  300 W
External Steam Supply System : Saturated Steam of 97% Dryness 
                                                           Pressure; 3.50~5.00 Bar   Flow Rate;  Max. 10 Kg/Hr
Water Source Pressure:  2.10~5.00 Bar,   Flow Rate:  Max. 50 ℓ/min
Vacuum System Water Ejector,   Water Pump (490W)
Net Weight 334 ㎏
Environment Conditions * Altitudes up to 2,000 meters.
* Temperature range of +5℃ to +40℃
* Maximum relative humidity of 80%
* Main supply voltage fluctuation of ±10% of nominal
* Installation Category (Overvoltage Category) Ⅱ,   Pollution Degree  2.