Tủ sấy

Tủ sấy,DSO-300D,Digisystem,Đài loan

Tủ sấy,DSO-300D,Digisystem,Đài loan
Memmert lồng ấp lạnh IPP800 (800 lít)

Cooled incubator, Peltier-technology
Model IPP 800

Standard equipment

Memmert lồng ấp lạnh IPP500 (500 lít)

Cooled incubator, Peltier-technology
Model IPP 500

Standard equipment

Memmert lồng ấp lạnh IPP400 (400 lít)

Cooled incubator, Peltier-technology
Model IPP 400

Standard equipment

Memmert lồng ấp lạnh IPP300 (300 lít)

Cooled incubator, Peltier-technology
Model IPP 300

Standard equipment

Memmert lồng ấp lạnh IPP200 (200 lít)

Cooled incubator, Peltier-technology
Model IPP 200

Standard equipment

Tủ ấm vi sinh INE 200 (Đức)

Precision incubator
Model INE 200

Standard equipment

Ventilation and Control

  • natural convection
  • continuous adjustment of pre-heated fresh air admixture
  • vent connection with restrictor flap
  • fuzzy-supported PID microprocessor controller with integrated autodiagnostic system with fault indication
  • solid state switching unit
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or ramp operation in combination with:
  • integrated digital timer for tempering profile with max. 4 segments, each segment adjustable from 1 min to 999 hours:
    DELAYED ON
    HEATING UP
    HOLD or HOLD set-temperature-dependent with guaranteed holding time
    COOLING DOWN
  • "Loop" function to repeat profile 1-99 times or endless
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, programme status and set-up values
  • resolution of display for set value and actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • incl. works calibration certificate for +37 °C
Tủ ấm memmert-INB-500

Precision incubator
Model INB 500

Standard equipment

Ventilation and Control

  • natural convection
  • continuous adjustment of pre-heated fresh air admixture
  • vent connection with restrictor flap
  • microprocessor PID-temperature controller with integrated autodiagnostic system with fault indicator
  • one Pt100 sensor class A in 4-wire-circuit
  • integrated digital timer (1 min. up to 99 h 59 min) to switch off heating to stand-by mode
  • digital LED- display of set and actual temperature as well as remaining process time
  • resolution of display for set value and actual value 0,5
Tủ ấm memmert-INB-400

Precision incubator
Model INB 400

Standard equipment

Ventilation and Control

  • natural convection
  • continuous adjustment of pre-heated fresh air admixture
  • vent connection with restrictor flap
  • microprocessor PID-temperature controller with integrated autodiagnostic system with fault indicator
  • one Pt100 sensor class A in 4-wire-circuit
  • integrated digital timer (1 min. up to 99 h 59 min) to switch off heating to stand-by mode
  • digital LED- display of set and actual temperature as well as remaining process time
  • resolution of display for set value and actual value 0,5 °C
Tủ ấm memmert-INB-300

Precision incubator
Model INB 300

Standard equipment

Ventilation and Control

  • natural convection
  • continuous adjustment of pre-heated fresh air admixture
  • vent connection with restrictor flap
  • microprocessor PID-temperature controller with integrated autodiagnostic system with fault indicator
  • one Pt100 sensor class A in 4-wire-circuit
  • integrated digital timer (1 min. up to 99 h 59 min) to switch off heating to stand-by mode
  • digital LED- display of set and actual temperature as well as remaining process time
  • resolution of display for set value and actual value 0,5 °C
Tủ ấm memmert-INB-200

Precision incubator
Model INB 200

Standard equipment

Ventilation and Control

  • natural convection
  • continuous adjustment of pre-heated fresh air admixture
  • vent connection with restrictor flap
  • microprocessor PID-temperature controller with integrated autodiagnostic system with fault indicator
  • one Pt100 sensor class A in 4-wire-circuit
  • integrated digital timer (1 min. up to 99 h 59 min) to switch off heating to stand-by mode
  • digital LED- display of set and actual temperature as well as remaining process time
  • resolution of display for set value and actual value 0,5 °C

Overtemperature protection (double)

  • in case of total breakdown of sensor, the heating is switched off at approx. 3 °C above set value
  • in case of failure of the switching element, the heating will be controlled by an additional relay approx. 3 °C above the set temperature
  • in case of a faulty sensor (incorrect measuring values) or the total breakdown of the controller the heating is switched off at approx. 10 °C above the max. oven temperature by the mechanical temperature limiter TB protection class 1
  • for very sensitive and/or valuable load in terms of being non-reproducable, we recommend ovens of our E- and P-class guaranteeing an even higher safety standard
Tủ ấm memmert-UNE-500PA

Universal oven "Paraffin Oven"
Model UNE 500 PA

Standard equipment

Control

  • fuzzy-supported PID microprocessor controller with integrated autodiagnostic system with fault indication
  • solid state switching unit
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or ramp operation in combination with:
  • integrated digital timer for tempering profile with max. 4 segments, each segment adjustable from 1 min to 999 hours:
    DELAYED ON
    HEATING UP
    HOLD or HOLD set-temperature-dependent with guaranteed holding time
    COOLING DOWN
  • "Loop" function to repeat profile 1-99 times or endless
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, programme status and set-up values
  • resolution of display for set value: 0,5 °C
  • resolution of display for actual value: 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • incl. works calibration certificate for +80 °C
Tủ ấm memmert-UNE-400PA

Universal oven "Paraffin Oven"
Model UNE 400 PA

Standard equipment

Control

  • fuzzy-supported PID microprocessor controller with integrated autodiagnostic system with fault indication
  • solid state switching unit
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or ramp operation in combination with:
  • integrated digital timer for tempering profile with max. 4 segments, each segment adjustable from 1 min to 999 hours:
    DELAYED ON
    HEATING UP
    HOLD or HOLD set-temperature-dependent with guaranteed holding time
    COOLING DOWN
  • "Loop" function to repeat profile 1-99 times or endless
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, programme status and set-up values
  • resolution of display for set value: 0,5 °C
  • resolution of display for actual value: 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • incl. works calibration certificate for +80 °C
Tủ ấm memmert-UNE-300PA

Universal oven "Paraffin Oven"
Model UNE 300 PA

Standard equipment

Control

  • fuzzy-supported PID microprocessor controller with integrated autodiagnostic system with fault indication
  • solid state switching unit
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or ramp operation in combination with:
  • integrated digital timer for tempering profile with max. 4 segments, each segment adjustable from 1 min to 999 hours:
    DELAYED ON
    HEATING UP
    HOLD or HOLD set-temperature-dependent with guaranteed holding time
    COOLING DOWN
  • "Loop" function to repeat profile 1-99 times or endless
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, programme status and set-up values
  • resolution of display for set value: 0,5 °C
  • resolution of display for actual value: 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • incl. works calibration certificate for +80 °C
Tủ sấy memmert-UNP-800

Universal oven
Model UNP 800

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNP-700

Universal oven
Model UNP 700

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNP-600

Universal oven
Model UNP 600

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNP-550

Universal oven
Model UNP 550

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNP-400

Universal oven
Model UNP 400

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNP-300

Universal oven
Model UNP 300

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNP-200

Universal oven
Model UNP 200

Standard equipment

Ventilation and Control

  • natural convection
  • adjustment of pre-heated fresh air admixture by air flap through process controller in 10% steps for each segment individually
  • vent connection with restrictor flap
  • adaptive, fuzzy-supported, multifunctional, digital microprocessor PID-controller
  • autodiagnostic system with fault indication
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or start of ramp operation
  • integrated timer for tempering profiles of up to 40 ramps, each segment adjustable from 1 min. up to 999 hours
  • multifunctional programming via menu on 8-digit alphanumeric digital display (language to be chosen via set-up):
    tempering profiles of up to 40 ramps
    time- and set-point dependent operation
    air flap adjustable in 10% steps
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, air flap position, programme status and set-up values
  • resolution of display for set value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C; for actual value 0,1 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • programme stored on power failure
  • parallel printer interface (incl. real-time clock with date function) for printing logging files, suitable all PCL3-compatible ink-jet printers (USB available via converter, see accessories)
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • chip card control incl. one MEMoryCard XL with 32 kB (up to 40 ramps)
  • incl. works calibration certificate for +160 °C
Tủ sấy memmert-UNE-800

Universal oven
Model UNE 800

Standard equipment

Ventilation and Control

  • natural convection
  • continuous adjustment of pre-heated fresh air admixture
  • vent connection with restrictor flap
  • fuzzy-supported PID microprocessor controller with integrated autodiagnostic system with fault indication
  • solid state switching unit
  • 2 Pt100 sensors Class A in 4-wire-circuit, mutually monitoring and taking over the performance at the same temperature value
  • digital 7-day-programme-timer with real time clock, precise minute setting, for one set value or ramp operation in combination with:
  • integrated digital timer for tempering profile with max. 4 segments, each segment adjustable from 1 min to 999 hours:
    DELAYED ON
    HEATING UP
    HOLD or HOLD set-temperature-dependent with guaranteed holding time
    COOLING DOWN
  • "Loop" function to repeat profile 1-99 times or endless
  • digital display (LED) of all set parameters, such as temperature, weekdays, time, programme status and set-up values
  • resolution of display for set value 0,5 °C; for actual value 0,1 °C below 99,9 °C, 0,5 °C above 100 °C
  • long-term logging (ring store) of all relevant data, GLP-conforming as data logger - 1024 kB
  • serial interface RS 232 including MEMMERT Software "Celsius" for programming and documentation
  • incl. works calibration certificate for +160 °C