Máy sinh hóa tự động

Máy sinh hóa tự động Cobas c 311

Máy sinh hóa tự động Cobas c 311

Roche - USA

 

 The cobas c 311 analyzer offers...

Comprehensive features in a compact footprint
  • Full menu, including general chemistries, TDM s, DAT s, and serum proteins
  • On–board capacity of 42 channels and 3 ISE s
  • 300 tests per hour
Convenience through standardization
  • Common ready–to–use reagent packs and user interface across cobas® platforms means less training and enhanced productivity
  • Online updates and enhanced remote services via cobas® e–services
Control laboratory operations
  • Automatic data flag processing of requesting repeats, dilutions without operator intervention
  • With Middleware Solutions, functions include archiving, autoverification, reflex testing, and delta checking
Confidence in results
  • Clot detection and test specific serum indices ensure reliable results
  • Non–contact ultra–sonic mixing results in homogeneous distribution of reactants
  • Common analytics yield comparable patient results across cobas® platforms
  • Provent Hitachi instrument reliability
  • cobas c 311 analyzer -
    Technical Specifications
  • System

    Automated, discrete clinical chemistry analyzer intended for the in vitro quantitative/qualitative determination of analytes in body fluids

    System Components

    Self contained floor model analyzer comprised of the analytical unit and control unit

    Sample Throughput

    300 photometric tests per hour

    Number of Channels

    42 channels and 3 ISE s

    Programmable Parameters

    Maximum: 117 photometric, 3 ISE tests, 8 formulas, 3 serum indices

    Sample Material

    Serum/plasma, urine, CSF

    Sample Input/Output

    Sample disk with 108 positions plus: W1 position for ISE cleaning solution, W2 position for ISE activator, Real STAT interrupt

    Sample Cups and Tubes

    Sample Container

    Diameter x length

    Primary sample tube

    16mm x 100mm

    Primary sample tube

    16mm x 75mm

    Primary sample tube

    13mm x 100mm

    Primary sample tube

    13mm x 75mm

    Hitachi standard cup

    17mm x 38mm, 2.5ml

    Hitachi micro cup

    8mm x 37mm, 1.5ml

    False bottom tube

    13mm x 75mm, one type definable

    Sample Clot Detection

    Available (pressure sesitive clot detection system)

    Liquid Level Sensor

    Capacitance sensing technology

    Sample Barcode Types

    NW7 (Codabar); Code 39; ITF; Code 128

    Control Unit

    Microsoft Windows XP, Pentium IV Processor

    System Interfaces

    RS–232 serial interface

    Sample Data Base

    10,000 samples (routine, STAT, and QC samples)

    Calibration Methods

    Start–up, re–calibration. For photometric assays: Linear, non–linear multi points, 2 point calibration, K–factor. Up to 100 calibrators pre–programmable. Storage of up to 180 curves. Preventative calibration of stand–by cassettes. Two k–factor can be defined for different sample types.

    QC Methods

    Real–time QC, individual QC, cummulative QC. Up to 100 different controls pre–programmable. Preventative QC after calibration of stand–by cassettes. Auto QC (without operator intervention).

    Electrical Requirements

    Power rating

    AC 208V AC/60Hz (US/Canada)

    Power supply fluctuation

    No significant power supply fluctuation (operating on 208/230V AC, max power supply change: ± 10%)

    Overvoltage category

    II

    Polution degree

    2

    Power consumption

    1.5 kVA for analytical unit; 0.5 kVA for control unit

    Electrical installation

    Technical standard class C,
    Required eathing < 10 Ω,
    Bonding impedance < 0.1Ω at 30 A,
    Insulation resistance > 10MΩ at 500 V

    Water/Waste Requirements

    Bacteria–free, deionized water

    < 10 cfu/mL

    Conductivity

    > 10 MΩ resistance

    Water pressure

    5015 to 25 psi (1.054 – 1.76g/cm2)

    Water supply volume

    40 L/h

    Operating Conditions

    Ambient temperature

    18 to 32° C

    Ambient humidity

    45 – 85% (non–condensing)

    Noise Output

    <70 dB(A) for surrounding

    Physical Dimensions

    Depth

    859 mm

    34 in

    Height

    1260 mm

    50 in

    Height level of monitor  

    1380–1570 mm      

    54.3–61.8 in

    Width

    1325 mm

    52 in

    Weight

    270 kg

    595 lb

    Sampling System

    Sample pipetting volume

    1.5–35 µL in 0.1 µL increments

    Detection of sample clogging

    Pressure sensitive clot detection system

    Liquid Level Sensor

    Capacitance sensing technology