Máy X-quang

Máy x-quang cao tần,EVA 750/525/325,Comed,Korea

Máy x-quang cao tần,EVA 750/525/325,Comed,Korea

 

 


 

 

 
New concept of high performance general radiographic system.
One-Body X-ray control system.
HFG
High Performance and Compact Size
Generator, easy to move and can be installed in the small area.


 


 

 
Multiple-positoned radiography function is more comfortable to the patient. User- friendly and a small radiation of action is one of the good point. Easy to aquire lateral radiography as the tube arm rotates flat to 180

 
 


 
ITEM
EVA-HF 325
EVA-HF 525
EVA-HF 750
X-RAY TUBE
MODEL
E7239X
E7239X
VARIAN or TOSHIBA
FOCAL SPOT
1.0 / 2.0
1.0 / 2.0
0.6 / 1.2 or 1.0 / 2.0
OPERATING VOLTAGE
40-125KVP (300mA)
40-125KVP (500mA)
40-150KVP (700mA)
TARGET ANGLE
16°
16°
16°
ANODE HEAT STORAGE
140,000 HU
140,000 HU
300,000 HU
HI-TRANS
METHODE
INVERTER (40kHz)
INVERTER (40kHz)
INVERTER (40kHz)
MAX VOLTAGE
125kVp
125kVp
150kVp
MAX CURRENT
300mA
500mA
700mA
POWER
37.5kW
40kW
50kW
CONTROLLER
KVP STEP
1 kVp (40-125kVp)
1 kVp (40-125kVp)
1 kVp (40-150kVp)
TIME STEP
1msec-5sec
1msec-5sec
1msec-5sec
mA STEP
25, 50, 75, 100, 150,
200, 250, 300mA
25, 50, 75, 100, 150, 200,
250, 300, 400, 500mA
50, 100, 200, 300, 400,
500, 600, 700mA
TYPE
High Frequency Inverter
High Frequency Inverter
High Frequency Inverter
COLLIMATOR
METHODE
MANUAL
MANUAL
MANUAL
MAX VOLTAGE
150KV
150KV
150KV
MAX WINDOWS
35cm x 35cm (SID 65cm)
35cm x 35cm (SID 65cm)
35cm x 35cm (SID 65cm)
MIN WINDOWS
5cm x 5cm (SID 100cm)
5cm x 5cm (SID 100cm)
5cm x 5cm (SID 100cm)
GENERAL
ELECTRICAL
1?220V 37.5KW
1?220V 40KW
3?380V 50KW
USE CASSETTE MAX SIZE
14″x 17″
14″x 17″
14″x 17″
INDICATOR
LCD, programable APR
LCD, programable APR
LCD, programable APR

 


 

 Multiple-positoned radiography function is more comfortable to the patient. 
User- friendly and a small radiation of action is one of the good point.
Easy to aquire lateral radiography as the tube arm rotates flat to 180


   


 Powerful Invert Generator System


 

 High frequency type of radiography system with versatility and high performance.
Versatile and excellent Radiography system for whole parts of body.


   


 

 All system is controlled by microprocessor program.
The best ability as a circuit-integrated system.


   


 

 System-Self-Diagnosis and Self-diagnostic circuitry standard on each unit.
Equipped with closed loop for X-ray tube current as well as kVp, minimizing 
potential errors and needs for re-adjustments. 
for X-ray tube current as well as kVp, minimizing potential errors and need 
for re-adjustments.


   


 

 . Technologically Advanced High Performance Imaging
. Expanded Dynamic Range
. Shorter exposure time, less radiation dose improved image quality
. High Frequency Generator


   


 Simple Design & User Convenience


 

 New concept of high performance operation console system.
More considerable for using.


   


 

 Controlled by multiple microprocessors assuring consistent and repeated X-ray operation service mode is used to calibrate the generator and repeated X-ray operation service mode is used to calibrate the generator


   


 

 For users, LCD has twice wide display.


   


 

 Convenient control system with APR option Programmed into the best one, so it is possible to radiate with simple operation. 
It can be changed by users.
Programmed into the best one, so it is possible to radiate.
with simple operation. It can be changed by users.


   


 

 Connected X-ray control system and display panel with cable.


   


 Versatile Functioned System


 

 Ceiling tube support system for stable and heavy work loads
It is designed to provide effortless positioning over an extension area for all types of general radiography and procedures


   


 

 The Bucky stand is designed for general purpose radiographic
Manufactured by radiography at chest, thorax spinal and skull of standing patient
The unit can be mounted on the wall or freestanding near to bucky table.


   


 

 It is possible to operate with general power on X-ray radiopraphy 
and can be used as a MOBILE CARE SYSTEM(option)
sources of electricity, and can be used as a 