Máy siêu âm

Máy siêu âm vi tính LogicScan 64

Máy siêu âm vi tính LogicScan 64

 Telemed -Lithuania

The LogicScan 64 ultrasound imaging system is a Color Doppler device. Its key features include digital Doppler multi-beam processing, which will increase frame rate during color and Power Doppler imaging and the novel hybrid signal processing module, for improving sensitivity.

LogicScan 64 FLT-1T Kit

The ultrasound scanner has been developed as compact, lightweight, battery powered color system.

 

Main information

 

Type / Order Code

Click on the

 photo for more details

Number of transducer ports

Power

Dimensions

W x D x H, mm

(see note 1)

Weight, kg

(see note 2)

Approval

Status

LogicScan 64 FLT-1T Kit

LogicScan 64 FLT-1T Kit

1

external power supply, charger:

100~240 VAC,

50~60 Hz

 315 x 250 x 28

1,5

Device is CE approved

full production

 

Note 1. Scanner shape looks perfect with Sony Vaio SZ notebook.

Note 2. Transducers, power supply and packing not included

Note 3. The list of compatible transducers see here.

 

LogicScan 64 ultrasound images

 

 
   

More LogicScan 64 ultrasound images and videos see at our FTP server.

 

LogicScan 64 FLT-1T photos

 

 

 

 

 

Common specifications

 

Imaging Modes

 

Ultrasound imaging

  • B

  • B+B

  • 4B

  • B+M

  • M

  • Color Doppler (CFM)

  • Power Doppler (PDI)

  • Directional Power Doppler (DPDI)

  • Pulsed Wave Doppler (PWD)

  • B+PWD (Duplex)

  • B+CFM/PDI/DPDI+PWD (Triplex)

 
  • ultrasound image size: automatically adjustable to screen resolution

  • gray scale: 256

  • color scale: 256

  • full motion and full size real-time ultrasound imaging, up to 120 fps (depends on selected scan depth, scan angle, focus mode, High Line Density setting, computer speed)

  • cineloop recording/play: several thousands frames (depends on computer memory size and scan mode)

  • zoom mode: from 60% to 600% in all modes (Scan, Freeze, B, B+B, 4B, Doppler modes, M-zoom, cineloop and etc)

  • viewing area variable for frame rate maximizing: 6 steps

  • thumbnail mode: up to 32 images

  • "FREEZE" mode

   

Scanning Method

 

Transducers

  • electronic linear

  • electronic convex

  • electronic microconvex

  • scanning depth: 2-30 cm

 
  • the list of compatible transducers see here:

    • from 2,0 MHz to 10,0 MHz

    • multifrequency

  • automatic transducer recognition

   

Color Doppler

 

Pulsed Waved Doppler

  • PRF variable: 0.5-9 kHz

  • wall filter settings: 3 steps (5%, %10%, 15% PRF)

  • gain control: 50 dB

  • angle steering for linear transducers: ±10°

  • real-time spatial filter: 4 values

  • CFM palette: 10 maps

  • PDI palette: 11 maps

  • B/Color priority control

  • color threshold control

  • CFM baseline control

  • Doppler frequency selection: 2 frequencies / each transducer

  • color frame averaging: 8 values

  • Transparent Color Mapping (TCM): 10 values

 
  • PRF variable: 1-10 kHz

  • wall filter settings: 16 steps (2.5-20% PRF)

  • gain control: 50 dB

  • angle steering for linear transducers: ±10°

  • real-time trace line with automatic calculation of spectrum parameters

  • stereo sound: volume control

  • PWD palette: 12 maps

  • Doppler frequency selection: 2 frequencies / each transducer

   

Focusing

 

Processing

  • digital transmit focusing

  • multi focus mode:

    • transmit/receive focusing

    • programmable focus area presets

  • dynamic focus mode:

    • transmit variable focus

    • dynamic receive focus

 
  • High Line Density scan mode for better resolution

  • TGC Control, 5 sliders 40 dB

  • dynamic range: 120 dB, 8 values

  • overall gain control

  • M - mode sweep speed control

  • acoustic power control

  • variable frame averaging

  • brightness, contrast

  • advanced gamma control: 8 fixed curves, 8 user defined (custom)

  • scan direction, rotation, up-down controls

  • negative / positive control

  • bi-linear interpolation

  • echo enhancement control

  • noise rejection function

  • speckle reduction and structure improvement PureView: 8 algorithms

  

Telemedicine

 
 
   

Automatic Image Optimization

 

Power

  • single click auto adjustment:

    • B-image: gain, dynamic range, TGC sliders

    • Color Doppler: CFM/PDI/DPDI gain

    • Pulsed Waved Doppler: baseline, invert, PRF

 
  • 100~240V AC, 50~60 Hz

  • battery powered

    • battery type: Li-Ion technology

    • battery life: 90 min (actual battery life will vary depending on scan mode)

    • battery charging time: 2 hours

   

Functions

 

Interface Customization

  • mouse / trackball / keyboard operation

  • image and video save / load

  • unlimited programmable presets for clinically specific imaging

  • anatomical icons with transducer position indicator

  • direct e-mail sending with image or video attachment via Internet

  • DICOM file push to server

  • printing on system printer

  • TV output via computer display adapter

 
  • the set of predefined skin schemes for software interface

  • the set of predefined buttons images

  • Multilanguage support, languages:

    • Chinese

    • English

    • Italian

    • Korean

    • Lithuanian

    • Magyar

    • Polish

    • Romanian

    • Russian

    • Spanish

  • B+M, B+PW layout position, size

  • ultrasound area size

  • font size

   

General Measurements and Calculations

 

Human Measurements and Calculations Packages

  • B and Color Doppler mode general measurements and calculations

    • Distance

    • Length (method: 1 trace)

    • Area, Circumference (methods: 1 ellipse, 1 trace, 1 distance)

    • Volume (methods: 1 distance, 2 distances, 3 distances, 1 ellipse)

    • Angle (methods: 2 distances, 3 distances)

    • Stenosis % (methods: 2 distances, 2 ellipse or trace areas)

    • A/B Ratio (methods: 2 distances, 2 ellipse or trace areas, 2 ellipse or trace circumferences)

  • M mode general measurements and calculations

    • Distance, Time, Velocity

    • Heart Rate (methods: 1 beat, 2 beats)

    • Stenosis % (method: 2 distances)

    • A/B Ratio (methods: 2 distances, 2 times, 2 velocities)

  • PW mode general measurements and calculations

    • One-point PW measurements and calculations:

      • Velocity

      • Pressure Gradient (PG)

    • Two-points PW measurements and calculations:

      • Velocities difference

      • Pressure Gradients (PG) difference

      • Time interval

      • Acceleration

      • Resistivity Index (RI)

      • Heart Rate (methods: 1 beat, 2 beats)

      • Velocity minimum and maximum

      • Pressure Gradient (PG) minimum and maximum

    • Trace-based PW measurements and calculations:

      • Trace Time

      • Trace Velocity min, max, mean

      • Trace Pressure Gradient (PG) min, max, mean

      • Velocity Time Integral (VTI)

      • Pulsatility Index (PI)

    • A/B Ratios of one-point PW measurements:

      • Velocities A/B Ratio

      • Pressure Gradients (PG) A/B Ratio

    • A/B Ratios of two-point PW measurements:

      • Velocity differences A/B Ratio

      • Pressure Gradient (PG) differences A/B Ratio

      • Time differences A/B Ratio

      • Accelerations A/B Ratio

      • Resistivity Indexes A/B Ratio

    • A/B Ratios of trace-based PW measurements:

      • Velocity means A/B Ratio

      • Pressure Gradient (PG) means A/B Ratio

      • Pulsatility Indexes A/B Ratio

      • Velocity Time Integrals A/B Ratio

 
  • Human General calculations package

    • Measurements: the same as general measurements of different modes (B, M, PW)

    • Calculations: BSA via Height and Weight, BSA via Weight

    • PW mode calculations: HR, SV using Flow Area, SV using Flow Diameter, SI, CO, CI, Area calculation using Continuity Equation (methods: Area and VTI, Area and Velocity, Diameter and VTI, Diameter and Velocity, Velocity Ratio (S/D, D/S), dP:dt, Flow Volume (methods: Diameter, Area), PHT, MVA

  • Human Obstetrics / Gynecology (OB / GYN) calculations package

    • Measurements: LMP (entered or from calendar), AC, BPD, FL, HC, FTA, AAPD, ATD, TAPD, TTD, CRL, GS, HL, TL, UL, OFD, BOD, Cereb, Clav, Rad

    • Estimated date of birth (EDD) calculations: EDD(LMP), EDD(GA), EDD(AUA)

    • Ratios: FL / AC, FL / HC, FL / BPD, HC / AC, CI

    • Estimated Fetal Weight (EFW) calculations: EFW(AC), EFW(AC,BPD), EFW(AC,FL), EFW(AC,HC), EFW(AC,FL,HC), EFW(AC,BPD,FL), EFW(AC,BPD,FL,HC), EFW(BPD,FL,FTA), EFW(BPD,ATD), EFW(BPD,TTD), EFW(BPD,TAPD,TTD), EFW(BPD,FL,TAPD,TTD)

    • Selected EFW values are used for calculation of Average EFW

    • Gestational Age (GA) calculations: GA(AC), GA(BPD), GA(CRL), GA(FL), GA(GS), GA(HC), GA(HL), GA(OFD), GA(TL), GA(UL), GA(HC/AC), GA(FTA),GA(ATD), GA(TAPD), GA(TTD), GA(BOD), GA(Cereb), GA(Clav)

    • Fetal Growth estimation (trending): AC(GA), BPD(GA), CRL(GA), FL(GA), GS(GA), HC(GA), HL(GA), OFD(GA), TL(GA), UL(GA), [FL/AC](GA), [FL/HC](GA), [HC/AC](GA), EFW(GA), AAPD(GA), ATD(GA), TAPD(GA), TTD(GA), BOD(GA), Cereb(GA), Rad(GA), Clav(GA)

    • Selected Growth Tables are visualized as Fetal Growth Curves

    • Software supports unlimited number of user-defined Growth Tables

  • Human Gynecology (GYN)

    • Measurements: length, height, width of uterus, cervix, ovaries, renals, follicles

    • Calculations: volumes of uterus, cervix, ovaries, renals, follicles

  • Human Abdominal exam measurements and calculations

    • Liver: Volume (CC, AP, LL diameters)

    • Gallbladder: Volume, Wall Thickness, Extrahepatic Bile Duct (EBD), Common Bile Duct (CBD), Common Hepatic Duct (CHD)

    • Pancreas: Head Diameter, Body Diameter, Tail Diameter, Pancreatic Duct Head, Pancreatic Duct Body

    • Spleen: Volume (length, width, thickness)

    • Gastrointestinal Tract: Appendix Wall Thickness, Appendix Diameter, Bowel Wall Thickness (at Stomach, Small Bowel, Large Bowel)

    • Urinary Bladder: Volume (length, height, width)

    • Right / Left Kidney: Volume (length, height, width), Pelvis Diameter

  • Human Urology

    • Measurements: length, height, width of kidneys, bladder, prostate, testes

    • Calculations: volumes of kidneys, bladder, prostate, testes; RUV (Residual Urine Volume)

  • Human Endocrinology

    • Measurements: length, width, thickness of thyroid lobes

    • Calculations: volumes thyroid lobes; volume of thyroid

  • Human Vascular exam measurements and calculations

    • Distance and area -based stenosis calculations at left (right) Subclavian, CCA (Common Carotid Artery), Bulb, ICA (Internal Carotid Artery), ECA (External Carotid Artery), Vertebral vessels at proximal, middle, distal locations

    • PSV/EDV (Peak Systole Velocity / End Diastole Velocity) ratios for each vessel and location

    • Ratios of velocities ICA PSV/CCA PSV, ICA EDV/CCA EDV, ICA PSV/CCA EDV, ECA PSV/CCA PSV, ECA EDV/CCA EDV, ECA PSV/CCA EDV at Rt. (Lt.) Prox. (Mid., Dist.) locations

  • Human Cardiology

    • Software supports the following measurements of Left Ventricle, Aortic Valve, Left Atrial: IVSd (Interventricular Septal Thickness, diastole), LVIDd (Left Ventricle Internal Diameter, diastole), LVPWd (Left Ventricle Posterior Wall Thickness, diastole), AOd (Aortic Root Dimension, diastole), IVSs (Interventricular Septal Thickness, systole), LVIDs (Left Ventricle Internal Diameter, systole), LVPWs (Left Ventricle Posterior Wall Thickness, systole), LADs (Left Atrial Dimension, systole).

    • Calculations: HR (Heart Rate), BSA (Body surface Area), Left ventricle volume (methods: Cubed, Teichholz, Gibson), SV (Stroke Volume), SI (Stroke Volume Index), EF (Ejection Fraction), CO (Cardiac Output), CI (Cardiac Index), STIVS (Interventricular Shortening), FS (Fractional Shortening), STPW (Posterior Wall Shortening), LVM (Left Ventricle Cardiac Mass), CMI (Cardiac Mass Index), LA/AO Ratio

 

Human/Veterinary OB Gyn packages: software supports unlimited number of user-defined GA tables, selected GA values are used for calculation of Average GA (Average Ultrasound Age - AUA).

Human/Veterinary Cardiology measurements package automatically displays hint images that show where and how appropriate measurements must be performed.

PW mode Human Cardiology measurements and calculations

  • Left Ventricle: LVOT Diam, LVOT VTI, LVOT Vmax, SV (Stroke Volume), SI (Stroke Volume Index), CO (Cardiac Output), CI (Cardiac Index), dP:dt (Delta Pressure : Delta Time), MPI (Left Ventricle Myocardial Performance Index)

  • Mitral Valve: MVA(PHT) (Mitral Valve Area using Pressure Half Time), MVA using Continuity Equation (LVOT Diam, MV VTI; LVOT Diam, MV Vmax), dP:dt, E/A ratio

  • Aortic Valve: AVA (Aortic Valve Area) using Continuity Equation (LVOT Diam, AV VTI; LVOT Diam, AV Vmax), AVI (Aortic Valve Index), DPI (Dimensionless Performance Index), AV PHT (Aortic Valve Pressure Half Time)

  • Right Ventricle: RVOT Diam, RVOT VTI, RVOT Vmax, dP:dt, RV MPI (Right Ventricle Myocardial Performance Index)

  • Tricuspid Valve: TVA (Tricuspid Valve Area) using Continuity Equation (RVOT Diam, TV VTI; RVOT Diam, TV Vmax); TV E/A ratio, TV PHT

  • Pulmonic Valve: PVA (Pulmonic Valve Area) using Continuity Equation (RVOT Diam, PV VTI; RVOT Diam, PV Vmax), PVI (Pulmonic Valve Index), DPI (Dimensionless Performance Index), PV PHT (Pulmonic Valve Pressure Half Time)

  • Pulmonary Vein; Hepatic Vein

  • Shunts: Qp:Qs (Pulmonary-Systemic Flow Ratio)

Veterinary Calculations Packages

 

Veterinary Calculations Packages

  • Canine OB

    • Measurements: GS, CRL, HD, BD

    • Gestational Age (GA) calculations: GA(BD), GA(CRL), GA(GS), GA(HD)

  • Feline OB

    • Measurements: HD, BD

    • Gestational Age (GA) calculations: GA(BD), GA(HD)

  • Ovine OB

    • Measurements: CRL

    • Gestational Age (GA) calculations: GA(CRL)

  • Bovine OB

    • Measurements: BD, CRL, HD, UD

    • Gestational Age (GA) calculations: GA(BD), GA(CRL), GA(HD), GA(UD)

 
  • Equine OB

    • Measurements: AOD, BPD, CRL, EOD, GS

    • Gestational Age (GA) calculations: GA(AOD), GA(BPD), GA(CRL), GA(EOD), GA(GS)

  • Llama OB

    • Measurements: BPD

    • Gestational Age (GA) calculations: GA(BPD)

  • Goat OB

    • Measurements: BPD

    • Gestational Age (GA) calculations: GA(BPD) for different species

  • Animal Cardiology

    • Left Ventricle, Aortic Valve, Left Atrial measurements: IVSd, LVIDd, LVPWd, AOd, IVSs, LVIDs, LVPWs, LADs

    • Calculations: HR, LV volume (Cubed, Teichholz, Gibson), SV, EF, CO, STIVS, FS, STPW, LA/AO

   

Recommended Computer Requirements

 

Ultrasound software

  • IBM PC compatible Desktop/Notebook/Tablet PC

  • screen resolution 1024x768 or more

  • CPU Core Duo / Core 2 Duo 1.6 GHz or faster

  • 1 Gb of RAM or more

  • Nvidia graphic card, 256 Mb, Cuda 2.3 support

  • USB 2.0 interface

  • Windows® XP SP3, Windows® Vista SP2, Windows® 7 (all versions 32/64-bit)

 
  • TELEMED Drivers Package (32/64-bit Windows®)

  • Echo Wave II software (32/64-bit Windows®)

  • 3DView plug-in (optional, 32-bit Windows® only)

  • PanoView plug-in (optional, 32-bit Windows® only)

  • SDK documentation / sample code (available by agreement)

  • Echo Wave II start-up time: 30 sec (Core 2 Duo 2.66 GHz, 2 Gb of RAM)

  

 

Transducer

Parameters

Applications

Photo

Type / Order Code

Biopsy Adapter

Transducer Central Frequency, MHz

System Frequencies, MHz

Radius of Curvature, mm

Field of View / Degree, mm

Click to enlarge PV6.5/10/64

Convex

PV6.5/10/64D

 

6.5

5.0

6.25

7.5

10

147

       
Click to enlarge EC6.5/10/64

Convex

EC6.5/10/64D

6.5

5.0

6.25

7.5

10

147

        
Click to enlarge C3.5/20/64

Convex

C3.5/20/64D

 

3.5

2.0

3.0

4.0

20

104

        
Click to enlarge C3.5/60/64

Convex

C3.5/60/64D

3.5

3.0

4.0

5.0

60

63

       
Click to enlarge HL9.0/40/64

Linear

HL9.0/40/64D

7.5

5.0

6.5

8.0

-

38

      
Click to enlarge LV7.5/65/64

Linear

LV7.5/65/64D

 

6.5

4.5

6.0

7.5

-

63

         

Photo

Type / Order Code

Biopsy Adapter

Transducer Central Frequency,

MHz

Avail. Freq., MHz

Radius of Curvature, mm

Field of View, degree / mm