DANH MỤC SẢN PHẨM

Tìm kiếm nâng cao

Hỗ trợ trực tuyến

Bình chọn

  • Bạn biết về trang web qua nguồn nào ?
  • Internet
  • Hội chợ,Triển lãm
  • Báo chí
  • Qua tổng đài 1080
  • Người thân,Bạn bè
  • Tờ rơi,Poster
  •  

Tỉ giá ngoại tệ

Đối tác

Thống kê

Số lượt truy cập 3401630   lần

61   khách hàng đang online

Máy siêu âm

Máy siêu âm Vivid 7 Dimension

Máy siêu âm Vivid 7 Dimension

GE

 

Definition. Technology. Performance.

Definition. Technology. Performance.

Our creative multi-dimensional formats clearly convey cardiac anatomy, synchronicity and viability. You get 4D images rendered online that look like an actual heart. And, the new 4D visualization tools offer you a new perspective on volume and dimension with the assistance of Depth Color Rendering and Stereo glasses –making it look real enough to touch.

4D

 http://www.gehealthcare.com/usen/ultrasound/images/dr4_l.jpg

4D depth color render. Two depth color render maps enhance depth perception in any 4D image.

 

Advanced TSI

http://www.gehealthcare.com/usen/ultrasound/images/tissuetracking_l.jpg

Advanced Tissue Synchronization Imaging (TSI) provides quantification of LV synchronicity information. Time-to-peak data is derived from the simple-to-use "red light/green light" visualizations.

9-slice

 http://www.gehealthcare.com/usen/ultrasound/images/9slice_l.jpg

See regional wall motion in a whole new way by slicing the left ventricle of a 4D full-volume dataset into nine equidistant short-axis views.

Real-time Color Flow Full Volume

http://www.gehealthcare.com/usen/ultrasound/images/cm4d_l.jpg

Assess hemodynamic information in color, in real time, in the same heart cycle.
You also have the option of viewing a 6-slice cross-section of the left ventricle.

Cutting-edge AFI

http://www.gehealthcare.com/usen/ultrasound/images/cmaf_l.jpg

Assessing and quantifying left ventricle wall motion is easy with our Automated Function Imaging (AFI) tool, which delivers reproducible, systolic, segmental and global assessments quickly and accurately. New simplified workflow with quick tips, and an adaptive ROI provide more robust and reproducible results for the non-expert, improving speed and confidence in understanding LV function.

Contrast Imaging

 http://www.gehealthcare.com/usen/ultrasound/images/contrastimaging_l.jpg

Get enhanced visualization of the LV border for wall-motion analysis and ejection fraction calculations in multi-dimensional and 4D full-volume imaging.

TT

 http://www.gehealthcare.com/usen/ultrasound/images/tissuetracking_l.jpg

Tissue Tracking provides easy recognition of regional and global wall left ventricular relaxation motion abnormalities.

SRI

http://www.gehealthcare.com/usen/ultrasound/images/straincurve_l.jpg

Strain Rate Imaging evaluates ischemic heart disease and true analysis of a specific piece of the myocardium.

4D LV Volume

http://www.gehealthcare.com/usen/ultrasound/images/4dlvvlm_l.jpg

Using the exceptional real-time full volume image quality produced by Vivid™ 7 Dimension, the 4D LV volume tailored package from TomTec Imaging Systems can provide a full assessment of the left ventricle, free of geometric assumptions and shape, in less than a minute. These valuable clinical tools ar available on both Vivid 7 Dimension and EchoPAC.

 

Multi-Dimensional and 4D Imaging

http://www.gehealthcare.com/usen/ultrasound/images/multidcolor_500.jpg

4D depth color render. Two depth color render maps enhance depth perception in any 4D image.

IMT Breakthrough

http://www.gehealthcare.com/usen/ultrasound/images/imtbreakthrough_500.jpg

IMT measuring technology slashes the time it takes to noninvasively measure the carotid artery’s intima-media thickness, which studies show may be an early indication of atherosclerosis. It allows you to streamline workflow and assess cardiovascular health faster.

4D CPI Breakthrough

 http://www.gehealthcare.com/usen/ultrasound/images/4dcpibreakthrough_500.jpg

We’ve enhanced your contrast imaging capabilities by adding 4D CPI (Coded Phase Inversion) on your 3V transducer. Now, you can get excellent sensitivity, resolution and tissue suppression in 4D imaging. Contrast agents enhance visualization of the left ventricular border for wall motion analysis and ejection fraction calculations in 4D.

Real-Time Full Volume

http://www.gehealthcare.com/usen/ultrasound/images/real_time_full.jpg

Real-Time Full Volume – constructs a complete 4D volume online during scanning, enabling you to see the information you are acquiring in real-time, for more complete and artifact-free depictions of the entire heart.

Tri-Plane Imaging

http://www.gehealthcare.com/usen/ultrasound/images/pisa.jpg

Tri-plane imaging – a first in cardiac ultrasound – provides a real-time simultaneous display of three images from the same heartbeat, ensuring a more accurate real-time assessment and quantification capabilities in grayscale, color and high-frame rate Tissue Velocity imaging.

 

Stress-Free Stress Echo

http://www.gehealthcare.com/usen/ultrasound/images/tri_stress_scores.jpg

Stress-free stress echo with Bi-plane and Tri-plane imaging enables complete acquisition of all stress echo views from just two imaging windows.

4D Tissue Synchronization Imaging

 http://www.gehealthcare.com/usen/ultrasound/images/4D_tsi_l.jpg

Advanced Tissue Synchronization Imaging (TSI) provides quantification of LV synchronicity information. Time-to-peak data is derived from the simple-to-use "red light/green light" visualizations.

Bull’s Eye Report Formats and TSI Surface Mapping

http://www.gehealthcare.com/usen/ultrasound/images/tsi_bullseye.jpg

Bull s Eye Report Formats and TSI Surface Mapping - communicate cardiac dyssynchrony in a visual display that should be more familiar to EP physicians.

Blood Flow Imaging (BFI)

http://www.gehealthcare.com/usen/ultrasound/images/bfi_caroti2.jpg

Blood Flow Imaging (BFI) – new vascular imaging mode gives clinicians a better understanding and delineation of directional blood flow in vessels.