Máy X-quang

Thiết bị đọc xử lý hình ảnh X-quang kỹ thuật số và chuẩn đoán CR-975

Thiết bị đọc xử lý hình ảnh X-quang kỹ thuật số và chuẩn đoán CR-975

Kodak

 

DIRECTVIEW CR 975 System

The DIRECTVIEW CR 975 system maximizes throughput, productivity and patient satisfaction.

  • Reduces radiographer queuing and allows images to be forwarded directly to multiple networks and the exam room.
  • Offers faster throughput, easier cassette loading, expanded software capabilities, and reduced service access requirements for greater placement flexibility.

 

Fast Throughput

  • Maximizes productivity with “drop-and-go” workflow and fast, reliable cassette processing.
  • Processes up to 101 cassettes an hour and handles 16 cassettes at one time.
  • Enables image review in 34 seconds and cassette reuse in 40 seconds.
 

Productivity

  • Enables radiographers to perform most system functions away from the main unit.
  • Connects to PACS, laser printers and DICOM format devices.
  • Facilitates storage, retrieval and distribution of entire radiography record

Ease of Training

  • Minimizes training time with consistent, intuitive user interface.

Patient Data Protection

  • Prevents unauthorized viewing with automatic security screensaver, and optional user name and password protections.
  • Minimizes training time with consistent, intuitive user interface.
  • Dimensions
  • Height: 52 in. (132.1 cm) (41 in. [104.1 cm] at cassette station)
  • Width: 41 in. (104.1 cm)
  • Depth: 30 in. (76.2 cm)
  • Weight: 956 lb. (433.6 kg)
  • Monitor: 17.0 in. flat-panel touch screen, full color, 1280 x 1024 matrix
  • hroughput
  • Capable of handling up to 8 exposed cassettes and 8 erased cassettes at a time
  • Throughput: up to 101 cassettes/hour
  • Time from cassette insertion to image at network: 34 seconds or less*
    *For 35 x 43 cm cassette. Times for other radiography cassette sizes are the same or less. Time for image at a network device is dependent on network performance.

Grayscale Resolution

  • 4096 (12-bit grayscale)

Power

  • Includes an on-board, uninterruptible power supply (UPS)
  • 100–120 VAC 10 Amps 50/60 Hz
  • 200–240 VAC 5 Amps 50/60 Hz

Heat Dissipation

  • 1400 BTU/HR Max

Network

  • 10 BaseT, 100 BaseT, 1000 BaseT Network Adapter

Regulatory

  • FDA, UL, cUL, CE Mark
  • System is certified as a casual patient contact medical device