Máy cắt trĩ

Dụng cụ khâu nối vòng,CDH29,Ethicon,Mỹ

Dụng cụ khâu nối vòng,CDH29,Ethicon,Mỹ

 

 

 

 

 

 

 Ethicon Endo-Surgery Circular Staplers are designed for open and endoscopic procedures and are available in both curved and straight shafts in multiple diameters. The Curved Intraluminal and Straight Intraluminal Staplers are designed to improve access and visibility by attaching the tissue to the anvil shaft away from the main body of the instrument. This instrument has been designed to facilitate insertion, operation, and removal.

Our Endoscopic Curved Intraluminal Stapler is a sealed-shaft, low-reflective circular stapler with a Tissue Compression Indicator with graduated markings. These indicate the approximate compressed tissue thickness at specific positions within the gap setting scale. With a longer sealed shaft, low profile anvil, and low reflective surfaces, it maintains pneumoperitoneum, improved access, and visibility for minimally invasive procedures.

Features of our intraluminal staplers include:

  • Controlled Tissue Compression – allows you to control the amount of compression applied to tissue depending on the clinical situation
  • Adjustable Height Staples – accommodate compressed tissue thickness from 1.0mm to 2.5mm. No other circular stapler is indicated for a wider range*
  • Large Tissue Compression Scale designed for visibility and ease of use
  • 5.5mm open-leg staple length allows for proper staple formation in thick tissue
  • Available in four sizes – proper matching to diameter of the lumen
  • Patented cutting washer delivers audible and tactile feedback as an indication that the firing sequence is complete
  • Designed for easy insertion, operation, and removal
  • Ergonomic design – non-slip grip and reduced grip span provides increased comfort and control

Procedure applications are for end-to-end, end-to-side, and side-to-side anastomosis.

Please click on the links below to see detailed descriptions of the MRI-related information regarding these products.

ENDOPATH Endoscopic Curved Intraluminal Circular Staplers

PROXIMATE Curved and Straight Intraluminal Staplers

Please contact our Customer Support Center at 1-800-873-3636 or via email at customersupport@eesus.jnj.com for more information.

CODE
SHAFT LENGTH
HEAD DIAMETER
LUMEN
OPEN LEG LENGTH
ADJUSTABLE CLOSED STAPLE HEIGHT
EA/BX
SDH21A
18cm
21mm
12.4mm
5.5mm
1.0-2.5mm
3
SDH25A
18cm
25mm
16.4mm
5.5mm
1.0-2.5mm
3
SDH29A
18cm
29mm
20.4mm
5.5mm
1.0-2.5mm
3
SDH33A
18cm
33mm
24.4mm
5.5mm
1.0-2.5mm
3
CDH21A
18cm
21mm
12.4mm
5.5mm
1.0-2.5mm
3
CDH25A
18cm
25mm
16.4mm
5.5mm
1.0-2.5mm
3
CDH29A
18cm
29mm
20.4mm
5.5mm
1.0-2.5mm
3
CDH33A
18cm
33mm
24.4mm
5.5mm
1.0-2.5mm
3
ECS21A
28cm
21mm
12.4mm
5.5mm
1.0-2.5mm
3
ECS25A
28cm
25mm
16.4mm
5.5mm
1.0-2.5mm
3
ECS29A
28cm
29mm
20.4mm
5.5mm
1.0-2.5mm
3
ECS33A
28cm
33mm
24.4mm
5.5mm
1.0-2.5mm
3

 

We also continue to offer our existing line of circular staplers – the PROXIMATE® ILS Curved and Straight Intraluminal Staplers and for endoscopic procedures, the ENDOPATH® ILS Endoscopic Curved Intraluminal Stapler.

Procedure applications are for end-to-end, end-to-side, and side-to-side anastomosis.

CODE
SHAFT LENGTH
HEAD DIAMETER
LUMEN
OPEN LEG LENGTH
ADJUSTABLE CLOSED STAPLE HEIGHT
EA/BX
SDH21
18cm
21mm
12.4mm
5.5mm
1.0-2.5mm
3
SDH25
18cm
25mm
16.4mm
5.5mm
1.0-2.5mm
3
SDH29
18cm
29mm
20.4mm
5.5mm
1.0-2.5mm
3
SDH33
18cm
33mm
24.4mm
5.5mm
1.0-2.5mm
3
CDH21
18cm
21mm
12.4mm
5.5mm
1.0-2.5mm
3
CDH25
18cm
25mm
16.4mm
5.5mm
1.0-2.5mm
3
CDH29
18cm
29mm
20.4mm
5.5mm
1.0-2.5mm
3
CDH33
18cm
33mm
24.4mm
5.5mm
1.0-2.5mm
3
ECS21
28cm
21mm
12.4mm
5.5mm
1.0-2.5mm
3
ECS25
28cm
25mm
16.4mm
5.5mm
1.0-2.5mm
3
ECS29
28cm
29mm
20.4mm
5.5mm
1.0-2.5mm
3
ECS33
28cm
33mm
24.4mm
5.5mm
1.0-2.5mm
3

* Based on IFU comparisons