DANH MỤC SẢN PHẨM

Tìm kiếm nâng cao

Hỗ trợ trực tuyến

Bình chọn

  • Bạn biết về trang web qua nguồn nào ?
  • Internet
  • Hội chợ,Triển lãm
  • Báo chí
  • Qua tổng đài 1080
  • Người thân,Bạn bè
  • Tờ rơi,Poster
  •  

Tỉ giá ngoại tệ

Đối tác

Thống kê

Số lượt truy cập 1540021   lần

56   khách hàng đang online

Máy đo độ đông máu

Máy xét nghiệm đông máu bán tự động Coagulometer CL4

Máy xét nghiệm đông máu bán tự động Coagulometer CL4

Behnk-Đức

 

 
  – Whole blood
– Blood plasma
– Capillary citrated blood
– Normal and micro-volumes
– For all commercial reagents
– Maintenance free

The measuring system

A sensor monitors the ball rotating on the bottom of the cuvette. When a large coagulum is created, the ball is stopped on the wall of the cuvette. A smaller coagulum either slows the ball´s movement or directs it towards the centre of the cuvette. The following three parameters lead to the positive detection of a developing coagulum: The ball does not pass the sensor because it has stopped; the ball is no longer detected, because it has been directed toward the centre of the cuvette; the impulse sensor detects a delay in the ball s path. Fibrinolyse measures the time taken for a sample to coagulate before measuring the time it takes for the coagulum to break up.

The calculator

The operation is simple and easy to understand. All normal calculation types can be selected in dialogue form with the printer. The programming status can be programmed by using the <E> key.

Handling

A register allows up to 40 patient samples to be prepared and then continually processed. Three assigned incubation positions enable a safe and continuous routine. Two reagent mixing positions and an incubation position for a Multi-Step® pipette round off the instrument. Three positions for reagents and one for the ball dispenser keep the working area organised.

Features:

– Four measuring channels
– Sample volumes between 150 and 400 µl
– Twelve incubation positions
– One incubation position for a Multi-Step® pipette
– One register for 40 samples
– Three positions for reagent containers
– One position for a ball dispenser
– One quiet thermo-printer
– One RS 232 interface
– Automatically saves calibration curves
– Error control during the coagulation process
– Automatic or manual start of the measurement
– Single or double determination

Technical data:

– Operating voltage: 120/230 V ±10 %
– Frequency range: 50–60 Hz
– Power consumption: 60 VA
– Dimensions: 300 x 200 x 545 mm (WxHxL)
– Weight: 13,4 kg